[PreviousPage] [Next Page] [Tableof Contents]

8. COIN SELECTOR

HANDLING THE COIN JAM

If the coin is rejected when the REJECT BUTTON is pressed, open the coinchute door and open the selector gate. After removing the jammed coin, puta normal coin in and check to see that the selector functions correctly.


CLEANING THE COIN SELECTOR

The coin selector should be cleaned once every 3 months. When cleaning,follow the procedure below:

1. Turn the power for the machine off. Open the coin chute door.

2. Open the gate and dust off by using a soft brush (made of wool, etc.).

3. Remove and clean smears by using a soft cloth and dipped in wateror diluted chemical detergent and then squeezed dry.

4. Remove the CRADLE. When removing the retaining ring (E-ring), be verycareful not to bend the shaft.

5. Remove stains from the shaft and pillow portions by wiping off witha soft cloth, etc.

6. After wiping as per #5 above, further apply a dry cloth, etc. to causethe coin selector to dry completely.


Never apply machineoil, etc. to the coin selector. After cleaning the Coin Selector, inserta regular coin in the normal working status and ensure that the Selectorfunctions correctly.


COIN INSERTION TEST

Once a month, when performing the COIN SW TEST, simultaneously checkthe following:

1. Does the Coin Meter count satisfactorily?

2. Does the coin drop into the Cash box correctly?

3. is the coin rejected when inserted while keeping the REJECT BUTTONpressed down?