[Table of Contents] [Previous Page] [Next Page]

THROTTLE VOLUME


 

Loosen the 2 Nuts which secure the Volume Bracket to move the Volume Bracket.

Moving the Volume Bracket causes Adjust Gear mesh to be disengaged.

Adjust gear mesh and tighten the 2 Nuts.

Grip the Throttle Lever and check to ensure that the V. R. value variations are within the rotatable range of the Volume Shaft.

After finishing adjustments, be sure to perform Throttle Volume setting on the Volume Setting screen in the Test mode.

In order to prevent an electric shock and short circuit, be sure to turn power off before performing work by touching the interior parts of the product. Be careful so as not to damage wirings. Damaged wiring can cause an electric shock or short circuit accident.

Turn power off.

Perform the above adjustment procedure.

Disconnect the connector connected to the Throttle Volume.

Take out the 2 Nuts which secure the Volume Bracket, and remove the Volume Bracket with the Volume as is attached.

Remove the Volume Gear from the Volume Shaft, and replace the Volume by removing from the Bracket.

After the replacement, perform Volume Setting in the Test mode.