DEWATERING FROM THE AIR FILTER
Remove the Rear Lid of the Mechanism Base to have the water tank appear in the inner portion on the right-hand side. Although the Air Drive Mechanism of the product automatically dewaters the water from inside the Air Filter, dispose the water from inside the Air Filter by periodically dewatering (every day in the period of high humidity). The drain water can be discharged into a sewer system.
Turn the Main SW of the AC Unit and Circuit Protector inside Front Cabinet OFF. Take out the S screws to remove the Rear Lid of the Mechanism Base. The Drain Tube from the Filter is connected to the water tank. Remove the Water Tank from the Mechanism Base by firmly holding the Drain Tube so as not to allow the tube to come off from the water tank. When dewatering is performed, water will gush out together with the compressed air. Be sure to firmly hold the Drain Tube so as not to allow the tube to come off from the water tank, and press the drain nozzle underneath the Filter in the horizontal direction. Unless the Tube is firmly held, the water can splash out in the periphery . The drained water can be discharged into a sewer system. After dewatering is finished, shake the end of the Drain Tube off to remove water thoroughly, put the tube end into the water tank, and return the water tank to the Mechanism Base.