[Table of Contents] [Previous Page] [Next Page]

18-2 CONNECTING THE COMMUNICATION CABLES

 


The Communication cables are made of Optic Fiber. Excessive bending can damage it. Handle with care.

 

The PROTECT TUBE is used to link plural machine units and the communication cables are caused to pass through the PROTECT TUBE. Depending on the number of machine units to be linked, connect the communication cables (optic fiber cables) in the manner shown in Figures 18. 2 f.

1) By taking off 2 screws, remove the HOLE LID of the side where the PROTECT TUBE is to be installed.

2) Attach CONNECTOR 22 to the both ends of FLEX TUBE, and assemble the PROTECT TUBE. First, disassemble CONNECTOR 22 (Fig. 18. 2 b).
3) First pass the plastic nut through the flex tube. Otherwise, the following work can not be performed and therefore, be very careful of this point.
4) Install the holder and then the "insert" for both ends of the flex tube by turning them as in bolts and nuts (Fig. 18. 2 c).
5) Tighten the plastic nut to the connector. At this time, pass the optic fiber cable through the flex tube ahead of time so as to allow the following work to be performed easily (Fig. 18. 2 d).
6) Install the PROTECT TUBE into the HOLE PLATE HOLE. Insert the connector into the HOLE PLATE HOLE, put the seal washer through and fasten the metal nut (Fig. 18. 2 e).

7) Connect the communication cable. Depending on the number of units to be connected, communication connections are different. Make connections correctly as shown below.

8) By using the 2 screws, install the Hole Plate to the position where the Hole Lid was.