If the coin is not rejected even when the REJECT button is pressed, open the coin chute door and open the selector gate. After removing the jammed coin, put a normal coin in and check to see that the selector correctly functions.
The coin selector should be cleaned once every 3 months. When
cleaning, follow the procedure below:
Turn the power for the machine OFF. Open the coin chute door.
Open the gate and dust off by using a soft brush (made of wool,
etc.).
Remove and clean smears by using a soft cloth dipped in water
or diluted chemical detergent and then wrung.
Remove the CRADLE. When removing the retaining ring (E ring).
be very careful so as not to bend the shaft.
Remove stain from the shaft and pillow portions by wiping off
with a soft cloth, etc.
After wiping off as per (5) above, further apply a dry cloth,
etc. to cause the coin selector to dry completely.
IMPORTANT!
Once every month when performing the Coin SW Test, simultaneously check the following: