16. TROUBLESHOOTING

In case a problem occurs, first check wiring connector connections.

PROBLEMS

CAUSE

COUNTERMEASURES

When the main power is not on, the machine is not activated. The power is not ON. Firmly insert the plug into the outlet.
Incorrect power source/voltage. Make sure that the power supply/voltage are correct.
AC Unit fuse blown off due to instantaneous overcurrent. First remove the cause of overcurrent, then replace the fuse (see Sec. 6).
514-5036-15000
FUSE 6.4 ØX 30 15000mA 125V
AC100~120V AREA
514-5037-8000
FUSE 6.4 ØX 30 8000rnA 250V
AC220~240V AREA
PTV screen is blackened and the fluorescent lamp does not light up. Power supply unit fuse blown off due to instantaneous overcurrent. First remove the cause of overcurrent, then replace the fuse.
514-5036-10000
FUSE 6.4 ØX 30 10000mA 125V
PTV screen is all blue. Defective connections in between each board. Make sure of correct connections in between each board.
The color of image on PTV screen is incorrect. Connector connections are defective. Check to see if connector connections of RGB and SYNC are correct.
Incorrect monitor adjustment. Make appropriate adjustments (see Sec. 13).
PTV screen has a color deviation. Affected by the periphery, such as other machines, location building's steel frames, etc. Make convergence adjustments (see Sec. 13).
Change installation direction/position. Move the other machines which cause the problem.
Sound is not emitted. Sound volume adjustment is not correct. Adjust the SWITCH UNIT's sound adjustment volume (control) (see Sec. 8).
Malfunctioning of sound BD and memory. Perform SOUND TEST (see Sec. 8).
Control panel and pedal not operable satisfactorily. V. R. position deviated, or V. R malfunctioning. Adjust or replace the V. R. (see Sec. 9 & 10).
ADJUST GEAR's engagement is not correct. Adjust the engagement of ADJUST GEAR (see Sec. 9 & 10).
SHIFT LEVER doesn't operate satisfactorily. Switch position deviated, or switch malfunctioning. Adjust or replace the Switch (see Sec. 11). 509-5566
SW MICRO TYPE
Steering Wheel reaction strength is insufficient. POWER ON CHECK not performed correctly. First turn the power off and then turn it back on again. Complete the POWER ON CHECK.
V. R. position deviated, or V. R. malfunctioning. Adjust or replace the V. R. (see Sec. 9).
Reaction mecha's secular change. Change DRIVE BD DIP SW setting (see Sec. 8 & 17).
Fluorescent lamp doesn't light up. Fluorescent lamp needs replacement. Replace the fluorescent lamp (see Sec. 14).