[Table of Contents] [Previous Page] [Next Page]

9 - 11 VOLUME SETTING

 

This setting item allows each volume value for SWING and INCLINING to be set.


When V. R. adjustment or replacement has been made, be sure to perform the setting in that particular V. R. value setting item.

 

VOLUME SETTING PROCEDURE

Set the volume by moving the Foot Controller fully within the moving range.

Operate the Foot Controller to change the volume values indicated beside SWING and INCLINING. The values in the parentheses display the previous setting.
Bring the arrow to "EXIT WITH SAVE" and press the Test button to have newly set contents registered, and the menu mode returns to the screen. If the NEUTRAL value for SWING is not within the range of 70~8F, the menu mode returns to the screen after displaying "WARNING: INVALID VALUE" for 5 seconds. Since normal operation can not be performed by playing in the above status, redo the settings. If the value is not within the range of 70~ 8F, the deviation or malfunctioning of the Volume may be the cause. By referring to 10 - 1, adjust or replace the Volume.
Bring the arrow to "EXIT WITHOUT SAVE" and press the Test button to have the menu mode return to the screen without changing the contents of setting.