REPLACEMENT OF MOTOR BRUSH

On the output test screen in the test mode, when 1P gun or 2P gun display indicates ON, if the gun does not vibrate, first check the switch unit's circuit protector. If the circuit protector is satisfactory, check the motor brush.

By referring to the figures below, remove the cover left, cover right and the grip.

Remove a total of 6 U nuts to withdraw the slide mecha. Pay attention to the wirings to remove the connector.

Take off the two screws from the lower part of the motor to remove the brush. If the motor brush is worn away as shown, replace the motor brush. When replacing the brush, be sure to replace brushes for both sides simultaneously.