8 . MAINTENANCE OF HANDLE AND SHIFT LEVER

 

 

In order to prevent an electric shock and short circuit, be sure to turn power off before performing work by touching the interior parts of the product.

Be careful so as not to damage wirings. Damaged wiring can cause an electric shock or short circuit accident.

This work should be performed by the Location's Serviceman. Performing work by non-technical personnel can cause shock hazard.

Don not touch places other than those specified. Touching places not specified can cause an electric shock accident.


In the test mode, if the handle V.R. value movements are irregular, adjust or replace the V.R. in the following procedure.

 

8 - 1 ADJUSTMENT AND REPLACEMENT OF SWING VOLUME

 

 

SETTING THE VOLUME

(1) In the test mode, have the V.R. value displayed on the screen.

 

(2) Remove the 11 screws from the right-hand side Panel Cover.

 

(3) Loosen the 2 screws which secure the Volume Bracket, and you can move the Volume Bracket.

 

(4) Moving the Volume Bracket disengages the gear mesh.

 

(5) Secure the handle to the centering position and adjust the gear mesh so that the position of Volume value is within the range 80+/-2H.

 

(6) Fasten the 2 securing brackets.

 

(7) Set the volume in the Volume Setting Mode.

 


REPLACING THE VOLUME

(1) Turn Power off.

 

(2) Disconnect the Connector.

 

(3) Remove the Volume bracket by taking out the 2 screws which secure the Volume Bracket.

 

(4) Remove the Volume Gear and Volume Bracket to replace the Volume. Adjust the gear mesh and ensure that Volume value display is within the range of 80+/-2H when the handle is in the centering position.

 


8 - 2 GREASING

 

In order to prevent electric shock and short circuit, be sure to turn off power before performing work by touching the interior parts of the product.

Be sure to use designated grease. Using undesignated grease can cause parts damage. Do not apply greasing to places other than those specified. Greasing to undesignated places can cause malfunctioning and the qualitative deterioration of parts.


Once in 3 months, apply greasing to Volume Gear Mesh Portion. For spray greasing, use GREASE MATE (P.No. 090-0066).


8 - 3 REMOVING THE SHIFT LEVER

 

In order to prevent an electric shock and short circuit accident, be sure to turn power off before performing work by touching the interior parts.

Be careful so as not to damage wirings. Damaged wirings can cause an electric shock or short circuit accident. Do not touch places other than those specified. Touching places not specified can cause an electric shock or short circuit accident.


If the Shift Lever operation is not satisfactory, remove the Shift Lever in the following procedure and replace the micro switch.

 

 

(1) Take out the 6 truss screws and remove the Shift Cover.

 

(2) Remove the 4 Hexagon Bolts which secure the Shift Lever.

 

(3) Carefully lift the Shift Lever so as no to damage the Shift Lever's wiring connections, and disconnect the connectors.

 

 


8 - 4 SWITCH REPLACEMENT

 

Each Micro switch is secured with 2 screws. Remove the 2 screws and replace the Micro switch.

After replacing the Switch, check to see if the switch is inputted as per Shift Lever operation in the Test Mode.

After replacing the Switch, check to see if the switch is inputted as per Shift Lever operation in the Test Mode.