COIN SELECTOR
HANDLING THE COIN JAM
If the coin is not rejected when the REJECT button is pressed, open the coin chute door and open the selector gate. After removing the jammed coin, put a normal coin in and check to see that the selector correctly functions.
CLEANING THE COIN SELECTOR
The coin selector should be cleaned once every 3 months. When cleaning, follow the procedure below:
1. Tum the power for the machine OFF. Open the coin chute door.
2. Open the gate and dust off by using a soft brush (made of wool, etc.).
3. Remove and clean smears by using a soft cloth dipped in water or diluted chemical detergent and then squeezed dry.
4. Remove the CRADLE.
When removing the retaining ring (E ring), be very careful so as not to bend the shaft.
5. Remove stain from the shaft and pillow portions by wiping off with a soft cloth, etc.
6. After wiping off as per 5. above, further apply a dry cloth, etc. to cause the coin selector to dry completely.
COIN INSERTION TEST
Once every month, when perl the Coin SW Test, simultaneously check the following:
Does the Coin Meter count satisfactorily?
Does the coin drop into the Cashbox correctly?
Is the coin rejected when inserted while keeping the Reject Button pressed down?