HANDLE: | Displays the HANDLE V.R. value. Make sure that the appropriate V.R. value is as follows: | ||
APPROPRIATE V.R. VALUE: | Under 2DH | <-- 7D~83H --> | Over D3H |
Left | Centering | Right | |
DIP SW: | Displays the setting status of DIP SWes on the DRIVE BD. |
The setting of DIP SW Nos. 1~4 on the DRIVE BD allows the handle's
weight (via "feeling") to be set and ON or OFF of POWER
ON CHECK to be selected. DIP SW Nos. 5 to 8 are to be OFF.
The DRIVE BD is mounted on the ASSY ELEC. Refer to 17-1 when changing
the settings.
NOTE: The bold portion refers to the setting at the time of
shipment.
When DIP SW changes are made, be sure to turn the power off
and then turn it back on again. The new setting is not effective
unless it is turned teach on again.
The handle's reaction mechanism is subject to a secular change.
When the reaction becomes lighter, change the DIP SW setting.
When malfunctioning occurs in the DRIVE BD, testing will not
be performed even if DRIVE BD TEST is selected. In this case,
the error No. will be displayed by the 7-SEG display on the DRIVE
BD.
Also, when a POWER-ON CHECK ERROR occurs, the 7-SEG. display data
repeatedly flashes. First check the handle mecha's V.R., the motor,
clutch, etc.