[Table of Contents] [Previous Page] [Next Page]

HANDLE: Displays the HANDLE V.R. value. Make sure that the appropriate V.R. value is as follows:
APPROPRIATE V.R. VALUE: Under 2DH <-- 7D~83H --> Over D3H
Left Centering Right
DIP SW: Displays the setting status of DIP SWes on the DRIVE BD.

DIP SW SETTING TABLE

The setting of DIP SW Nos. 1~4 on the DRIVE BD allows the handle's weight (via "feeling") to be set and ON or OFF of POWER ON CHECK to be selected. DIP SW Nos. 5 to 8 are to be OFF.

The DRIVE BD is mounted on the ASSY ELEC. Refer to 17-1 when changing the settings.

DIP SW SETTING

NOTE: The bold portion refers to the setting at the time of shipment.

When DIP SW changes are made, be sure to turn the power off and then turn it back on again. The new setting is not effective unless it is turned teach on again.

The handle's reaction mechanism is subject to a secular change. When the reaction becomes lighter, change the DIP SW setting.

DRIVE BD ERROR DISPLAY

When malfunctioning occurs in the DRIVE BD, testing will not be performed even if DRIVE BD TEST is selected. In this case, the error No. will be displayed by the 7-SEG display on the DRIVE BD.

Also, when a POWER-ON CHECK ERROR occurs, the 7-SEG. display data repeatedly flashes. First check the handle mecha's V.R., the motor, clutch, etc.